Product Introduction
OWT-1031 type x-ray thickness gauge is our research and development product on the basis of OWT-1021 type gamma ray thickness gauge, using X-ray sources instead of radioisotops. Features:open, shut down, no ray output when closed, safe and controllable. The thickness gauge has closed loop control function. The system selects high performance industrial control machine as main engine to process the C rack measuring system, and outputs the thickness deviation signal to the back adjustment (AGC).It uses an industrial display as an operating interface to carry out human machine dialogue, displaying various data and modifying parameters in real time.
System
OWT-1031 type X-ray thickness guage consists of primary and secondary meters.The primary meter includes:mechanical parts, X-ray sources, detectors and etc;The secondary meter includes: industrial display, industrial control system, digital display, cabinet, cooling machine and so on.
Measuring Range
Product model |
Measuring material |
Measuring range |
Certainty of measurement |
Measuring gap |
Response time |
Application range |
OWT1031 Seperate |
Common carbon steel, stainless steel, purple / brass, nickel, manganese steel |
0-1mm |
±0.1%Measuredthickness value±1μm |
65mm |
10ms-1000ms(adjustable) |
AGC unidirectional, reversible, continuous rolling mills are involved in closed loop control.
Communication RS232, RS485, PROFIBUS can be negotiated |
Aluminium strip |
0-4mm |
<1mm: ±0.1%±1μmIn 1mm-4mm:±0.1%±2μm |
65mm |
10ms-1000ms(adjustable) |
||
Gold strip |
0-0.15mm |
±0.1%±1μmMeasured thickness value |
65mm |
10ms-1000ms(adjustable) |
||
Silver strip |
0-0.30mm |
±0.1%Measured thickness value±1μm |
65mm |
10ms-1000ms(adjustable) |
Product model |
Measuring material |
Measuring range |
Certainty of measurement |
Measuring gap |
Response time |
Application range |
OWT1031 Whole |
Common carbon steel, stainless steel, purple / brass, nickel, manganese steel |
0-5mm |
<1mm:
±0.1%±1μm
In1mm-3mm :
±0.1%±2μm
In3mm-5mm :
±0.2%±2μm |
80mm |
10ms-1000ms(adjustable) |
AGC unidirectional, reversible, continuous rolling mills are involved in closed loop control.
Communication RS232, RS485, PROFIBUS can be negotiated |
Aluminium strip |
0-9mm |
<1mm:
±0.1%±1μm
In1mm-
3mm:
±0.1%±2μm
In3mm-
9mm: ±0.2%±2μm |
80mm |
10ms-1000ms(adjustable) |
||
Gold strip |
0-0.3mm |
±0.1%±1μm |
80mm |
10ms-1000ms(adjustable) |
||
Silver strip |
0-0.6mm |
±0.1%±1μm |
80mm |
10ms-1000ms(adjustable) |
General Analyzer Specifications
Supply voltage:AC220V/50HZ
Supply current:<3A
Operating temperature:-25℃—+65℃
Operating humidity :<70%
The interface signal of the AGC system:
analog value:Thickness difference output,±10Vcorresponding±100μm
digital value:232communication Or 485communication Or PROFIBUSommunication
Communication speed:115200bps
Zero-point voltage input range:7.5-8.5V
Display:Industrial display and external 4 - bit LED digital box